List the assessment methods to be used and the context and resources required for assessment. Copy and paste the relevant sections from the evidence guide below and then re-write these in plain English.
Element | Performance criteria |
Elements describe the essential outcomes. | Performance criteria describe the performance needed to demonstrate achievement of the element. |
1. Prepare for a fluorescence test | 1.1 Identify seed to be tested and complete records 1.2 Prepare working sample from submitted sample 1.3 Prepare the required number of replicates of 100 seeds 1.4 Prepare substrate as prescribed for a germination test using dormancy breaking treatments if necessary 1.5 Place replicates in a germination cabinet/room |
2. Assess germinated seeds | 2.1 Count off and record all un-germinated seeds and abnormal seedlings 2.2 Examine normal seedlings under ultra violet light 2.3 Count off and record normal seedlings that have fluorescent roots under ultra violet light 2.4 Count off and record normal seedlings that do not have fluorescent roots under ultra violet light 2.5 Minimise exposure of bare skin to ultra violet light 2.6 Complete enterprise worksheet |
3. Maintain a safe work environment | 3.1 Record, calculate and report results of test 3.2 Collect and dispose of laboratory and hazardous waste safely 3.3 Clean and store apparatus and equipment |
The candidate must be assessed on their ability to integrate and apply the performance requirements of this unit in a workplace setting. Performance must be demonstrated consistently over time and in a suitable range of contexts.
The candidate must provide evidence that they can:
prepare for a fluorescence test
assess seedlings using ultra violet light
count and record test results
prepare replicates from working sample
test to determine the presence of seeds of annual ryegrass species in perennial ryegrass seedlots
maintain a safe work environment
The candidate must demonstrate knowledge of:
enterprise and/or legal traceability requirements
enterprise standard operating procedures (SOPs)
fluorescence testing procedures
relevant work health, safety and environment requirements
seed biology
the role of the International Seed Testing Association (ISTA) and the ISTA Rules for Seed Testing
Assessors must satisfy current standards for RTOs.