Assessor Resource

MSL905004
Perform non-standard calibrations

Assessment tool

Version 1.0
Issue Date: May 2024


This unit of competency describes the skills and knowledge to recognise non-conforming calibration work, research and select the most appropriate test method or calibration procedure for a given measurement request, and then conduct the calibration. It also covers the ability to modify and revise existing procedures or substitute alternative instruments and measurement standards, when necessary.

This unit applies to calibration technicians/specialists who carry out calibrations in first, second and third party laboratories, and laboratories where testing and/or calibration forms part of inspection or product certification. They work with limited guidance and results of their work are checked by the laboratory manager, quality inspector or designated signatory.

The unit requires personnel to use a wide variety of precision measuring equipment and standards and cope with deviations from the explicit procedural instructions detailed in standard procedures and work instructions. When deviations do occur, each case must be documented, technically justified, authorised and accepted by the client.

No licensing or certification requirements exist at the time of publication. However, regulations and/or external accreditation requirements for laboratory operations exist, so local requirements should be checked. Relevant legislation, industry standards and codes of practice within Australia must also be applied.

You may want to include more information here about the target group and the purpose of the assessments (eg formative, summative, recognition)

Submission Requirements

List each assessment task's title, type (eg project, observation/demonstration, essay, assingnment, checklist) and due date here

Assessment task 1: [title]      Due date:

(add new lines for each of the assessment tasks)


Assessment Tasks

Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.
Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.

Observation Checklist

Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice Yes No Comments/feedback
Perform individual tests and document each step in the calibration procedure to ensure repeatability of measurement 
Critically analyse readings to confirm they are the result of a valid measurement and record data as required (as-found or before adjustment) 
Adjust device under test to bring readings within tolerance and record results (as-left or after adjustment) if required 
Analyse resulting test data to detect trends or inconsistencies that would significantly affect the accuracy or validity of test results 
Seek appropriate advice when result interpretation is outside authorised scope of approval 
Document compliance/non-compliance with requirements of test and/or specifications 
Estimate and document uncertainty of measurement in accordance with workplace procedures 
Record the results of each test/calibration accurately, unambiguously and objectively 
Ensure confidentiality of workplace information in accordance with workplace procedures 
Prepare and issue a final report for the job/item detailing testing carried out, statement of compliance and all other required information 
Report any non-compliance and verify next course of action with supervisor 
Attach calibration labels, equipment stickers, quality control tags and tamper resistant seals as required in workplace procedures 
Report all changes and deviations that may have a significant influence on the test 
Store test equipment/measurement standards and results in accordance with workplace procedures 
Identify non-conforming calibration tasks and requests and analyse their significance 
 
 
 
 
 
Identify hazards and use the appropriate personal protective equipment (PPE), safety equipment and procedures 
 
 
Perform individual tests and document each step in the calibration procedure to ensure repeatability of measurement 
 
 
 
Document compliance/non-compliance with requirements of test and/or specifications 
 
 
Prepare and issue a final report for the job/item detailing testing carried out, statement of compliance and all other required information 
 
 
 
 

Forms

Assessment Cover Sheet

MSL905004 - Perform non-standard calibrations
Assessment task 1: [title]

Student name:

Student ID:

I declare that the assessment tasks submitted for this unit are my own work.

Student signature:

Result: Competent Not yet competent

Feedback to student

 

 

 

 

 

 

 

 

Assessor name:

Signature:

Date:


Assessment Record Sheet

MSL905004 - Perform non-standard calibrations

Student name:

Student ID:

Assessment task 1: [title] Result: Competent Not yet competent

(add lines for each task)

Feedback to student:

 

 

 

 

 

 

 

 

Overall assessment result: Competent Not yet competent

Assessor name:

Signature:

Date:

Student signature:

Date: