Elements and Performance Criteria
- Plan and prepare.
- Work instructions and operational details are obtained using relevant information, confirmed and applied for planning and preparation purposes.
- Safety (OHS) requirements are followed in accordance with safety plans and policies.
- Signage and barricade requirements are identified and implemented.
- Material quantity requirements are calculated in accordance with plans, specifications and quality requirements.
- Materials appropriate to the work application are identified, obtained, prepared, safely handled and located ready for use.
- Environmental requirements are identified for the project in accordance with environmental plans and statutory and regulatory authority requirements, and are applied.
- Identify design requirements for various monuments.
- Range of monuments covered by AS4204 Headstones and cemetery monuments, and features and components involved in monumental construction are identified and applied.
- Legislation, regulations and codes relating to masonry work are identified and site features influencing design are applied from site visit or report.
- Prepare plans and specifications for construction and installation.
- Foundation design is selected in accordance with AS4204, job safety analysis (JSA) and safe work method statements, proposed monument and foundations.
- Materials are selected in accordance with regulations, site conditions and customer requirements.
- Drawings and specifications are prepared to requirements of approving authority, where applicable.
- Check details, edit drawings and specifications for submission.