  1. Plan and prepare work
  2. Work requirements and generator and/or alternator auxiliary plant are identified from appropriate personnel and documentation, in accordance with workplace procedures
  3. Generator and/or alternator auxiliary running up and loading schedule is ascertained from relevant documentation, in accordance with workplace procedures and site requirements
  4. Inspection, preoperational tests and field preparations for generator and/or alternator auxiliary plant service are carried out, in accordance with workplace procedures and manufacturers' recommendations
  5. Generator and/or alternator auxiliary plant operational prerequisites are established, in accordance with workplace procedures and manufacturers' recommendations
  6. Sequence for recommissioning of generator and/or alternator auxiliary plant is determined, in accordance with workplace procedures and site requirements
  7. Operate generator/alternator auxiliaryplant
  8. Generator and/or alternator auxiliary plant is monitored and observed, in accordance with workplace procedures, to detect deviations from required operating conditions
  9. Corrective actions are taken to rectify generator and/or alternator auxiliary plant abnormalities, in accordance with workplace procedures and manufacturers' recommendations
  10. Test generator/alternator auxiliaryplant operation
  11. Generator and/or alternator auxiliary plant is observed for correct operational response, in accordance with workplace procedures
  12. Corrective action is taken, in accordance with workplace procedures, when response does not meet with documentation, generator or alternator auxiliary plant integrity or personnel safety requirements
  13. Generator and/or alternator auxiliary plant is returned to required operational status upon completion of testing, in accordance with workplace procedures
  14. Analyse generator/alternator auxiliaryplant faults
  15. Corrective actions to rectify generator and/or alternator auxiliary plant faults are determined, in accordance with workplace procedures
  16. Generator and/or alternator auxiliary plant integrity and personnel safety is maintained, in accordance with workplace procedures, and in consultation with appropriate personnel and technical and operational documentation
  17. Monitor and inspect generator/alternator auxiliaryplant
  18. Generator and/or alternator auxiliary plant is monitored and inspected, in accordance with workplace procedures, for normal operation or to detect deviations
  19. Corrective action is taken, in accordance with workplace procedures
  20. Appropriate personnel are notified, in accordance with workplace procedures, when defects are detected
  21. Complete documentation