Elements and Performance Criteria
- Conduct HRSGstart up
- Preoperation conditions of the Heat Recovery Steam Generator (HRSG) and gas turbine are established, in accordance with workplace procedures
- Minimum operation of gas turbine is established and supported, in accordance with workplace procedures and manufacturers' specifications
- Monitoring of HRSG drum level, feedwater flow, steam and metal temperature rates of rise, steam pressure rate of rise and control of steam flow and drainage is carried out, in accordance with manufacturers' specifications and workplace procedures
- Exhaust temperature, flow to HRSG and gas turbine power output are adjusted, in accordance workplace procedures, to achieve required steam conditions and demand
- HRSG plant is operated within limits of its' design, in accordance with workplace procedures.
- HRSG plant is monitored, in accordance with workplace procedures, to detect deviations from required operating conditions
- Corrective action is taken to rectify HRSG abnormalities, in accordance with manufacturers' recommendations and workplace procedures
- Analyse HRSGfaults
- Plan and prepareHRSG start upwork
- Work requirements are identified from relevant personnel and documentation, in accordance with workplace procedures
- Preoperational checks are carried out on plant, in accordance with manufacturers' recommendations and workplace procedures and site requirements
- Minimum operation of gas turbine is established and supported, in accordance with workplace procedures and manufacturers' specifications
- Monitoring of HRSG drum level, feedwater flow, steam and metal temperature rates of rise, steam pressure rate of rise and control of steam flow and drainage is carried out, in accordance with manufacturers' specifications and workplace procedures
- Exhaust temperature, flow to HRSG and gas turbine power output are adjusted, in accordance workplace procedures, to achieve required steam conditions and demand
- HRSG plant is operated within limits of its' design, in accordance with workplace procedures.
- HRSG plant is monitored, in accordance with workplace procedures, to detect deviations from required operating conditions
- Corrective action is taken to rectify HRSG abnormalities, in accordance with manufacturers' recommendations and workplace procedures
- Test HRSG plant operation
- HRSG plant is observed, in accordance with workplace procedures, for correct operational response
- Corrective action is taken, in accordance with workplace procedures, when response does not meet documentation, plant integrity or personnel safety requirements
- HRSG plant is returned to required operational status upon completion of testing, in accordance with workplace procedures
- Corrective action is taken, in accordance with workplace procedures
- HRSG plant integrity and personnel safety is maintained, in accordance with workplace procedures, and through consultation with appropriate personnel and technical and operational documentation
- Appropriate personnel are notified, in accordance with workplace procedures, when defects are detected
- Complete documentation
- Documentation is updated, in accordance with workplace procedures
Range Statement