Google Links

Follow the links below to find material targeted to the unit's elements, performance criteria, required skills and knowledge

Elements and Performance Criteria

  1. Plan and prepare network systemoperations
  2. Power generation network system and associated equipment operational prerequisites are established, in accordance with H.V. system operating procedures
  3. Sequence for operation of power generation network system sections and equipment is created for a range of potential scenarios, in accordance with H.V. system operating procedures
  4. Power generation network system forecast is based on assessment of data and relevant information, in accordance with H.V. system operating procedures
  5. Manage and control network system
  6. Power generation network system demand is managed using a contingency plan and strategies to maintain quality of supply, in accordance with legislative requirements and H.V. system operating procedures
  7. Power generation network system voltage and current requirements are assessed, evaluated and managed to maintain stability and H.V. system integrity
  8. Voltage load profiles are identified and adhered to, in accordance with power generation network system, to minimise transmission losses
  9. Power generation network system load shedding sequence and priorities are monitored and managed, to ensure H.V. system integrity
  10. Power generation network system data is monitored and managed, for normal operation or to detect deviations
  11. Corrective actions to rectify abnormalities in power generation network system are implemented, following assessment of data, in accordance with H.V. system operating procedures
  12. Resources to meet power generation network system requirements are managed, in accordance with H.V. system operating procedures
  13. Analyse and respond to network system faults
  14. Operation and management of power generation network system protection program is evaluated to determine nature and cause of faults
  15. Communication with key stakeholders is established managed, to assist in identifying nature and source of H.V. system interference
  16. Corrective action is taken, in accordance with H.V. system operating procedures
  17. Power generation network system integrity and personnel safety are managed, in accordance with H.V. system operating procedures, and in consultation with appropriate personnel and technical and operational documentation including contingency plans
  18. Review incident response and preventative procedures
  19. Alternative responses to contingencies are identified and assessed, in accordance with system operating procedures
  20. Alternative responses to contingencies are documented and managed, in accordance with system operating procedures
  21. Complete documentation
  22. Documentation is updated, in accordance with workplace procedures