  1. Plan for plant operation
  2. Work, power generation plant and resource requirements are identified, in accordance with workplace procedures, from relevant information and documentation
  3. Preoperational checks of power generation plant operations are carried out, in accordance with workplace procedures and site requirements
  4. Operate generator and excitation system
  5. Synchronising requirements are assessed and evaluated, in accordance with workplace procedures to ensure generator and excitation system stability
  6. Generator and excitation system is monitored and observed, in accordance with workplace procedures, to detect deviations from normal operating conditions
  7. Corrective actions are taken to rectify generator and excitation system abnormalities, in accordance with manufacturers' recommendations and workplace procedures
  8. Control generation of electrical energy
  9. Reactive power generation and voltage regulation requirements are assessed and the generator and excitation system is controlled to achieve desired output, in accordance with workplace procedures
  10. Generator stabilities and operating limits are assessed and the generator and excitation system is controlled to maintain those limits, in accordance with workplace procedures and manufacturers' recommendations
  11. Generator cooling systems and limits are monitored and assessed, and the excitation system is controlled to maintain those limits, in accordance with workplace procedures and manufacturers' recommendations
  12. Coordinate generation control
  13. Output of generators is adjusted to meet electricity demand whilst observing operating requirements, in accordance with workplace procedures
  14. Generator and excitation system and power generating plant key indicators are monitored and adjusted, in accordance with workplace procedures, to maintain limits and detect deviations from normal operating conditions
  15. Generator and excitation system integrity and continuity of supply are maintained, in accordance with workplace procedures
  16. Consultation with appropriate personnel is undertaken, in accordance with workplace procedures
  17. Generator and excitation system is operated at optimum efficiency, in accordance with workplace procedures
  18. Monitor systemandplant
  19. Generator and excitation system or power generating plant is monitored, in accordance with workplace procedures, for normal operation or to detect deviations
  20. Corrective actions are taken, in accordance with workplace procedures
  21. Appropriate personnel are notified, in accordance with workplace procedures, when defects and abnormal operating conditions are detected
  22. Analyse systemand plant faults
  23. Corrective actions to rectify faults are determined, in accordance with workplace procedures
  24. Generator and excitation system or power generating plant integrity is maintained, in accordance with workplace procedures, through consultation with appropriate personnel and reference to technical and operational documentation
  25. Appropriate personnel, including specialists, are arranged for investigation of identified operational abnormalities, in accordance with workplace procedures
  26. Complete documentation