Elements and Performance Criteria
- Plan for the analysis of and develop solutions for, problems in single and three phase low voltage circuits
- OHS practices/procedures and environmental and sustainable energy procedures, which may influence the analysis and development of solutions for problems in single and three phase low voltage circuits, are reviewed and determined.
- Purpose of the analysis and development of solutions for problems in single and three phase low voltage circuits is established after data is analysed and expected outcomes of the work are confirmed with the appropriate personnel.
- Organisational established procedures on policies and specifications for the analysis and development of solutions for problems in single and three phase low voltage circuits are obtained or established with the appropriate personnel.
- Testing procedures are discussed with/directed to the appropriate personnel in order to ascertain the project brief.
- Testing parameters are established from organisational established procedures on policies and specifications.
- Equipment/tools and personal protective equipment are selected based on specified Performance Criteria and established procedures.
- Work roles and tasks are allocated according to requirements and individuals' competencies.
- Work is prioritised and sequenced for the most efficient/effective outcome, completed within an acceptable timeframe to a quality standard and in accordance with established procedures.
- Liaison and communication issues with other/authorised personnel, authorities, clients and land owners are resolved and activities coordinated to carry out work.
- Risk control measures are identified, prioritised and evaluated against the work schedule.
- Relevant work permits are secured to coordinate the performance of work according to requirements and/or established procedures.
- Carry out the analysis of and develop solutions for problems in single and three phase low voltage circuits
- Circuit/systems modelling is used to evaluate alternative proposals as per established procedures.
- OHS and sustainable energy principles, functionality and practices to reduce the incidents of accidents and minimise waste are incorporated into the project in accordance with requirements and/or established procedures.
- Decisions for the analysis and development of solutions for problems in single and three phase low voltage circuits are made on the basis of safety and effective outcomes according to requirements and/or established procedures.
- Mathematical and/or engineering models of the analysis and development of solutions for problems in single and three phase low voltage circuits are used to analyse the effectiveness of the finished project as per requirements and established procedures.
- Technical advice is given regarding potential hazards, safety risks and control measures so that monitoring and preventative action can be undertaken and/or appropriate authorities consulted, where necessary, in accordance with requirements and established procedures.
- Essential knowledge and associated skills are applied to analyse specific data and compare it with compliance specifications to ensure completion of the project within an agreed timeframe according to requirements.
- Testing of single and three phase low voltage circuits is undertaken according to requirements and established procedures.
- Work teams/groups are arranged/coordinated/evaluated to ensure planned goals are met according to established procedures.
- Solutions to non-routine problems are identified and actioned, using acquired essential knowledge and associated skills, according to requirements.
- Quality of work is monitored against personal performance agreement and/or established organisational and professional standards.
- Strategic plans are developed incorporating organisation initiatives as per established procedures.
- Complete the analysis of and develop solutions for problems in single and three phase low voltage circuits
- Final review of the analysis and implementation of developed solutions for problems in single and three phase low voltage circuits is undertaken to ensure they comply with all requirements and include all specifications and documentations needed to complete the project.
- Appropriate personnel are notified of completion and reports and/or completion documents are finalised/commissioned.
- Reports and/or completion documents are submitted to relevant personnel/organisations for approval and, where applicable, statutory or regulatory approval.
- Approved copies of required documents are issued and records are updated in accordance with established procedures.