Employability Skills
Learning Outcomes and Application This unit of competency describes the skills and knowledge to calibrate test and measurement equipment in accordance with standard calibration procedures and documented test methods. These procedures/methods specify all associated reference standards, materials, equipment and methods to be used and the required parameters or quantities and ranges to be tested, including the criteria for rejection or approval.This unit applies to laboratory and calibration technicians who carry out tests and/or calibrations using standard calibration methods in first, second and third party laboratories, and laboratories where testing and/or calibration forms part of inspection or product certification. Personnel are not permitted to deviate from explicit instructions in any manner, modify the procedure, nor substitute alternative equipment. They work under limited supervision and results of their work are interpreted and checked by the laboratory supervisor, quality inspector or designated signatory.No licensing or certification requirements exist at the time of publication. However, regulations and/or external accreditation requirements for laboratory operations exist, so local requirements should be checked. Relevant legislation, industry standards and codes of practice within Australia must also be applied.
Duration and Setting X weeks, nominally xx hours, delivered in a classroom/online/blended learning setting.
Prerequisites/co-requisites
Competency Field Calibration
Development and validation strategy and guide for assessors and learners Student Learning Resources Handouts
Activities
Slides
PPT
Assessment 1 Assessment 2 Assessment 3 Assessment 4
Elements of Competency Performance Criteria              
Element: Perform calibration
  • Perform individual tests without variance according to the documented procedure to ensure repeatability of measurement
  • Confirm readings are the result of a valid measurement and record data as required (as-found or before adjustment)
  • Adjust device under test to bring readings within specification and record data (as-left or after adjustment) where required
  • Analyse resulting test data to detect trends or inconsistencies that would significantly affect the accuracy or validity of test results
  • Seek appropriate advice when interpretation of results is outside authorised scope of approval
       
Element: Document results
  • Estimate and document uncertainty of measurement in accordance with workplace procedures, where required
  • Document compliance/non-compliance with test requirements and/or specifications
  • Record the results of each test/calibration accurately, unambiguously and objectively
  • Ensure confidentiality of workplace information in accordance with workplace procedures
       
Element: Finalise calibration
  • Prepare and issue a final report on the job/item detailing testing carried out, traceability, statement of compliance and relevant information
  • Report any non-compliance and verify next course of action with supervisor
  • Attach calibration labels, equipment stickers, quality control tags and tamper resistant seals as required in accordance with workplace procedures
  • Store test equipment/measurement standards and results in accordance with workplace procedures
       
Element: Prepare items for calibration
  • Select the authorised calibration procedure in accordance with workplace procedures
       
Element: Identify hazards and use appropriate personal protective equipment (PPE), safety equipment and procedures
       
Element: Confirm all measuring equipment meets the laboratory's specification requirements and complies fully with the calibration procedure
       
Element: Assemble and set up specified reference standards and associated equipment prior to testing
       
Element: Verify performance of reference standards and measuring equipment prior to use and adjust or calibrate as necessary
       
Element: Identify and minimise potential sources of measurement error
  • Perform individual tests without variance according to the documented procedure to ensure repeatability of measurement
       
Element: Confirm readings are the result of a valid measurement and record data as required (as-found or before adjustment)
       
Element: Adjust device under test to bring readings within specification and record data (as-left or after adjustment) where required
       
Element: Analyse resulting test data to detect trends or inconsistencies that would significantly affect the accuracy or validity of test results
       
Element: Seek appropriate advice when interpretation of results is outside authorised scope of approval
  • Estimate and document uncertainty of measurement in accordance with workplace procedures, where required
       
Element: Document compliance/non-compliance with test requirements and/or specifications
       
Element: Record the results of each test/calibration accurately, unambiguously and objectively
       
Element: Ensure confidentiality of workplace information in accordance with workplace procedures
  • Prepare and issue a final report on the job/item detailing testing carried out, traceability, statement of compliance and relevant information
       
Element: Report any non-compliance and verify next course of action with supervisor
       
Element: Attach calibration labels, equipment stickers, quality control tags and tamper resistant seals as required in accordance with workplace procedures
       
Element: Store test equipment/measurement standards and results in accordance with workplace procedures
       

Submission Requirements

List each assessment task's title, type (eg project, observation/demonstration, essay, assignment, checklist) and due date here

Assessment task 1: [title]      Due date:

(add new lines for each of the assessment tasks)


Assessment Tasks

Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.
Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.

Observation Checklist

Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice Yes No Comments/feedback
Perform individual tests without variance according to the documented procedure to ensure repeatability of measurement 
Confirm readings are the result of a valid measurement and record data as required (as-found or before adjustment) 
Adjust device under test to bring readings within specification and record data (as-left or after adjustment) where required 
Analyse resulting test data to detect trends or inconsistencies that would significantly affect the accuracy or validity of test results 
Seek appropriate advice when interpretation of results is outside authorised scope of approval 
Estimate and document uncertainty of measurement in accordance with workplace procedures, where required 
Document compliance/non-compliance with test requirements and/or specifications 
Record the results of each test/calibration accurately, unambiguously and objectively 
Ensure confidentiality of workplace information in accordance with workplace procedures 
Prepare and issue a final report on the job/item detailing testing carried out, traceability, statement of compliance and relevant information 
Report any non-compliance and verify next course of action with supervisor 
Attach calibration labels, equipment stickers, quality control tags and tamper resistant seals as required in accordance with workplace procedures 
Store test equipment/measurement standards and results in accordance with workplace procedures 
Select the authorised calibration procedure in accordance with workplace procedures 
 
 
 
 
Perform individual tests without variance according to the documented procedure to ensure repeatability of measurement 
 
 
 
Estimate and document uncertainty of measurement in accordance with workplace procedures, where required 
 
 
Prepare and issue a final report on the job/item detailing testing carried out, traceability, statement of compliance and relevant information 
 
 
 

Forms

Assessment Cover Sheet

MSL904002 - Perform standard calibrations
Assessment task 1: [title]

Student name:

Student ID:

I declare that the assessment tasks submitted for this unit are my own work.

Student signature:

Result: Competent Not yet competent

Feedback to student

 

 

 

 

 

 

 

 

Assessor name:

Signature:

Date:


Assessment Record Sheet

MSL904002 - Perform standard calibrations

Student name:

Student ID:

Assessment task 1: [title] Result: Competent Not yet competent

(add lines for each task)

Feedback to student:

 

 

 

 

 

 

 

 

Overall assessment result: Competent Not yet competent

Assessor name:

Signature:

Date:

Student signature:

Date: