Unit of Competency Mapping – Information for Teachers/Assessors – Information for Learners
UEENEEP001B Mapping and Delivery Guide
Disconnect and reconnect fixed wired electrical equipment connected to a Low Voltage supply
Version 1.0
Issue Date: May 2024
Qualification | - |
Unit of Competency | UEENEEP001B - Disconnect and reconnect fixed wired electrical equipment connected to a Low Voltage supply |
---|---|---|---|
Description | 1) 1.1) This unit covers disconnecting and reconnecting fixed wired electrical equipment. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting and excludes disconnecting or reconnecting circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc); or installation of or alteration to any part of the fixed electrical wiring system (defined as electrical installing work). | ||
Employability Skills | 3)This unit contains Employability SkillsThe required outcomes described in this unit of competency contain applicable facets of Employability Skills. The Employability Skills Summary of the qualification in which this unit of competency is packaged will assist in identifying Employability Skill requirements. | ||
Learning Outcomes and Application | 4) This unit applies to any formal recognition for this standard at the aligned AQF 2/3 level or higher. | ||
Duration and Setting | X weeks, nominally xx hours, delivered in a classroom/online/blended learning setting. |
||
Prerequisites/co-requisites | Prerequisite Unit(s) 2) 2.1) CompetenciesCompetencies needed for hot waters servicing, pool servicing, mechanical maintenance, appliance servicing, emergency services and equipment repair. | ||
Competency Field |
Development and validation strategy and guide for assessors and learners | Student Learning Resources | Handouts Activities |
Slides PPT |
Assessment 1 | Assessment 2 | Assessment 3 | Assessment 4 | |
---|---|---|---|---|---|---|---|---|
Elements of Competency | Performance Criteria | |||||||
Element: Prepare to disconnect electrical equipment. |
| |||||||
Element: Disconnect electrical equipment. |
| |||||||
Element: Prepare to reconnect electrical equipment. |
| |||||||
Element: Reconnect electrical equipment. |
| |||||||
Element: Test the reconnected electrical equipment for safe operation. |
| |||||||
Element: Identify and report faults |
| |||||||
Element: Provide status report(s). |
|