Unit of Competency Mapping – Information for Teachers/Assessors – Information for Learners

UEPOPS442 Mapping and Delivery Guide
Monitor and coordinate the operation of a combined cycle gas turbine unit

Version 1.0
Issue Date: May 2024


Qualification -
Unit of Competency UEPOPS442 - Monitor and coordinate the operation of a combined cycle gas turbine unit
Description
Employability Skills
Learning Outcomes and Application This unit involves the skills and knowledge required to simultaneously operate and monitor combined cycle power generation plant. It involves the safe and effective management of energy production to meet demand using a combined cycle gas turbine unit.Combined cycle plant typically consists of a gas turbine and associated generator, Heat Recovery Steam Generator (HRSG), steam turbine and associated generator. Combined cycle power plant uses both the gas and steam turbines together to produce more electricity from the same fuel.Competency in this unit requires the ability to plan for plant operation,operate heat recovery steam generator,operate generator and excitation system,control generation of electrical energy,coordinate unit operations,monitor system/plant,test system/plant operation,analyse system/plant faults and complete all documentation. Individuals will, in general, work as an operator, in a power generation facility.Power generation plant operators are typically trained and authorised to isolate, prepare plant and issue permits to work.No licensing, legislative or certification requirements apply to this unit at the time of publication.Note: Workplace practiceThe application of the skills and knowledge described in this unit may require a licence or training permit to practice in the workplace where work is carried out on gas and electrical installations. Additional conditions may apply under state and territory legislative and regulatory licensing requirements.
Duration and Setting X weeks, nominally xx hours, delivered in a classroom/online/blended learning setting.
Prerequisites/co-requisites
Competency Field Operations
Development and validation strategy and guide for assessors and learners Student Learning Resources Handouts
Activities
Slides
PPT
Assessment 1 Assessment 2 Assessment 3 Assessment 4
Elements of Competency Performance Criteria              
Element: Monitor system/plant
  • Generator and excitation system and combined cycle plant to be monitored is physically identified, in accordance with workplace procedures
  • Generator and excitation system and combined cycle plant is monitored for normal operation to detect deviations, in accordance with workplace procedures
  • Corrective action is taken, in accordance with workplace procedures
  • Appropriate personnel are notified, in accordance with workplace procedures, when defects and abnormal operating conditions are detected
       
Element: Plan for plant operation
  • Safety issues, including Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) regulations, are identified, in accordance with workplace procedures and site requirements
       
Element: Work, combined cycle plant and resource requirements are identified from relevant information and documentation, in accordance with workplace procedures
       
Element: Preoperational checks are carried out on combined cycle plant, in accordance with workplace procedures and site requirements
       
Element: Operate heat recovery steam generator
  • Gas turbine exhaust, gas flow and power output are adjusted to achieve required steam flow and conditions, in accordance with workplace procedures and operating requirements
       
Element: Supplementary firing system is placed into and out of service, as required, in accordance with workplace procedures, to maintain steam flow and steam conditions
       
Element: Combined cycle plant is operated within limits of its design, in accordance with workplace procedures and site requirements
       
Element: Combined cycle plant is operated, monitored and observed, in accordance with workplace procedures, to detect deviations from required operating conditions
       
Element: Corrective action is taken to rectify abnormalities in combined cycle plant, in accordance with manufacturers' specifications and workplace procedures
       
Element: Operate generator and excitation system
  • Generator and excitation system is operated, in accordance with workplace procedures and manufacturer’s operating recommendations
       
Element: Synchronising requirements are assessed, evaluated and implemented, in accordance with workplace procedures, to ensure generator and excitation system stability
       
Element: Generator and excitation system is monitored and observed, in accordance with workplace procedures, to detect deviations from normal operating conditions
       
Element: Corrective actions are taken to rectify generator and excitation system abnormalities, in accordance with workplace procedures and manufacturers' recommendations
       
Element: Control generation of electrical energy
  • Generator output is adjusted to meet demand, in accordance with workplace procedures, whilst observing operating requirements
       
Element: Reactive power generation and voltage regulation requirements are assessed, in accordance with workplace procedures, to ensure the generator and excitation system is controlled to achieve desired output
       
Element: Generator stabilities and operating limits are assessed and the generator and excitation system is controlled to maintain those limits, in accordance with workplace procedures and manufacturers' recommendations
       
Element: Generator cooling systems and limits are monitored and assessed, and excitation system is controlled to maintain those limits, in accordance with workplace procedures and manufacturers' recommendation
       
Element: Coordinate generator and excitation systemoperations
  • Generator and excitation systems are operated, in accordance with workplace procedures, to meet workplace requirements whilst observing power generating plant limitations
       
Element: Generator and excitation systems are monitored and observed, in accordance with workplace procedures, to detect deviations from normal operating conditions
       
Element: Causes of abnormal generator and excitation system operating conditions are identified by analysing technical and operational data and information, in accordance with workplace procedures
       
Element: Corrective action is taken to rectify generator and excitation system abnormalities, in accordance with workplace procedures and site requirements
       
Element: Generator and excitation system integrity, personnel safety and continuity of supply are maintained, in accordance with workplace procedures
       
Element: Consultation with appropriate personnel is undertaken, in accordance with workplace procedures and site requirements
       
Element: Generator and excitation system is operated at optimum efficiency, in accordance with workplace procedures
  • Generator and excitation system and combined cycle plant to be monitored is physically identified, in accordance with workplace procedures
       
Element: Generator and excitation system and combined cycle plant is monitored for normal operation to detect deviations, in accordance with workplace procedures
       
Element: Corrective action is taken, in accordance with workplace procedures
       
Element: Appropriate personnel are notified, in accordance with workplace procedures, when defects and abnormal operating conditions are detected
       
Element: Test system/plant operation
  • Operational tests are performed, in accordance with workplace procedures
       
Element: Generator and excitation system and combined cycle plant is observed for correct operational response, in accordance with workplace procedures
       
Element: Corrective action is taken, in accordance with workplace procedures, when response does not meet documentation, combined cycle plant and generator and excitation system integrity or personnel safety requirements
       
Element: Generator and excitation system and combined cycle plant is returned to required operational status, in accordance with workplace procedures, upon completion of testing
       
Element: Analyse system/plant faults
  • Causes of abnormal generator and excitation system operating conditions are identified, in accordance with workplace procedures, by analysing technical and operational information
       
Element: Corrective actions to rectify faults are determined, in accordance with workplace procedures
       
Element: Generator and excitation system and combined cycle plant integrity and personnel safety are maintained, in accordance with workplace procedures, and in consultation with appropriate personnel and technical and operational documentation
       
Element: Appropriate personnel are organised, in accordance with workplace procedures for investigation of identified operational abnormalities
       
Element: Complete documentation
  • Combined cycle plant problems, movements, and status are reported, in accordance with workplace procedures
       
Element: Documentation is updated, in accordance with workplace procedures
       

Submission Requirements

List each assessment task's title, type (eg project, observation/demonstration, essay, assignment, checklist) and due date here

Assessment task 1: [title]      Due date:

(add new lines for each of the assessment tasks)


Assessment Tasks

Copy and paste from the following data to produce each assessment task. Write these in plain English and spell out how, when and where the task is to be carried out, under what conditions, and what resources are needed. Include guidelines about how well the candidate has to perform a task for it to be judged satisfactory.

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the Companion Volume Implementation Guide.

Copy and paste from the following performance criteria to create an observation checklist for each task. When you have finished writing your assessment tool every one of these must have been addressed, preferably several times in a variety of contexts. To ensure this occurs download the assessment matrix for the unit; enter each assessment task as a column header and place check marks against each performance criteria that task addresses.

Observation Checklist

Tasks to be observed according to workplace/college/TAFE policy and procedures, relevant legislation and Codes of Practice Yes No Comments/feedback
Generator and excitation system and combined cycle plant to be monitored is physically identified, in accordance with workplace procedures 
Generator and excitation system and combined cycle plant is monitored for normal operation to detect deviations, in accordance with workplace procedures 
Corrective action is taken, in accordance with workplace procedures 
Appropriate personnel are notified, in accordance with workplace procedures, when defects and abnormal operating conditions are detected 
Safety issues, including Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) regulations, are identified, in accordance with workplace procedures and site requirements 
 
 
Gas turbine exhaust, gas flow and power output are adjusted to achieve required steam flow and conditions, in accordance with workplace procedures and operating requirements 
 
 
 
 
Generator and excitation system is operated, in accordance with workplace procedures and manufacturer’s operating recommendations 
 
 
 
Generator output is adjusted to meet demand, in accordance with workplace procedures, whilst observing operating requirements 
 
 
 
Generator and excitation systems are operated, in accordance with workplace procedures, to meet workplace requirements whilst observing power generating plant limitations 
 
 
 
 
 
Generator and excitation system and combined cycle plant to be monitored is physically identified, in accordance with workplace procedures 
 
 
 
Operational tests are performed, in accordance with workplace procedures 
 
 
 
Causes of abnormal generator and excitation system operating conditions are identified, in accordance with workplace procedures, by analysing technical and operational information 
 
 
 
Combined cycle plant problems, movements, and status are reported, in accordance with workplace procedures 
 

Forms

Assessment Cover Sheet

UEPOPS442 - Monitor and coordinate the operation of a combined cycle gas turbine unit
Assessment task 1: [title]

Student name:

Student ID:

I declare that the assessment tasks submitted for this unit are my own work.

Student signature:

Result: Competent Not yet competent

Feedback to student

 

 

 

 

 

 

 

 

Assessor name:

Signature:

Date:


Assessment Record Sheet

UEPOPS442 - Monitor and coordinate the operation of a combined cycle gas turbine unit

Student name:

Student ID:

Assessment task 1: [title] Result: Competent Not yet competent

(add lines for each task)

Feedback to student:

 

 

 

 

 

 

 

 

Overall assessment result: Competent Not yet competent

Assessor name:

Signature:

Date:

Student signature:

Date: