Application
This competency normally applies to the individual who is required to determine the properties of explosive ordnance through the process of measuring and recording during initiation or firing, in a research environment. This unit may apply to an individual who will determine the properties of explosive ordnance independently or may contribute to the determination of the properties of explosive ordnance as a member of a collaborative team. | |
Prerequisites
Pre-requisite Unit/s | Nil |
Elements and Performance Criteria
ELEMENT | PERFORMANCE CRITERIA |
1. Plan for explosive ordnance testing | 1.1 Type of explosive ordnance and required test or analysis are identified and confirmed in accordance with organisation policy and procedures 1.2 Nature and type of effects or properties to be determined are identified 1.3 Appropriate methods of measuring and recording the desired effects or properties are investigated and selected 1.4 Appropriate firing or initiation techniques and methods are investigated and selected 1.5 Occupational health and safety (OH&S) principles and requirements are identified, incorporated in the plan and observed throughout the testing process 1.6 The test plan is prepared and reviewed |
2. Prepare for explosive ordnance testing | 2.1 Models, simulation and/or prototypes are tested and validated in accordance with established engineering principles 2.2 Modifications or alterations are incorporated into the testing processes based on validation results 2.3 Necessary equipment is either acquired or built given project constraints and available skills and materials 2.4 Experimental designs are developed in liaison with other staff and checked to ensure they meet OH&S regulations and standards 2.5 Apparatus is assembled, set up and calibrated 2.6 Routine standardisation procedures are performed prior to the test, and results are recorded in accordance with engineering procedures |
3. Perform explosive ordnance test | 3.1 Instrumentation required for data collection is tested for functionality in accordance with test requirements 3.2 Explosive ordnance initiation or firing mechanisms are prepared and tested in accordance with Range Standing Orders and organisation policy |
4. Recover equipment and validate results | 4.1 Measurement and recording equipment are recovered and required data is extracted 4.2 Data is analysed for anomalies and 'out of control' conditions and either accepted or rejected 4.3 Data is assessed for validity against required information, known previous test results and/or relevant reference materials 4.4 Test procedures are recorded and, if necessary, modifications to test procedures are recommended |
Required Skills
This describes the essential skills and knowledge and their level, required for this unit. |
Required Skills |
access, interpret and apply technical information related to explosive ordnance access, interpret and apply technical information related to explosives access, interpret and apply technical information related to measuring and recording apply explosive testing processes and techniques apply OH&S requirements develop and use computer programs related to testing develop explosive ordnance testing processes and techniques maintain documentation and records participate in the team use testing equipment |
Required Knowledge |
analysis processes and techniques characteristics, technical capabilities and limitations of explosive ordnance characteristics, technical capabilities and limitations of measuring and recording equipment composition of teams and roles and responsibilities of team members documentation and records requirements physics of explosions planning principles of team work and team aims and objectives properties and characteristics of relevant explosives relevant OH&S requirements validation processes |
Evidence Required
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for this Training Package. | |
Critical aspects for assessment and evidence required to demonstrate competency in this unit | Assessment must confirm the ability to: adhere to relevant OH&S and operational safety requirements safely handle explosives and explosive ordnance plan tests prepare for tests carry out tests and measurements document procedures record and validate results. Consistency in performance Competency should be demonstrated in a range of actual or simulated explosive ordnance contexts. |
Context of and specific resources for assessment | Context of assessment Competency should be assessed in the workplace or under conditions which accurately simulate a realistic workplace. Specific resources for assessment Access is required to: facilities and resources used in the research, development and proof of explosive ordnance, including a licensed explosive site and appropriate firing/test range. |
Method of assessment | This unit may be assessed with the following unit: PUADEFEO101D Work safely with explosive ordnance. In a public safety environment assessment is usually conducted via direct observation in a training environment or in the workplace via subject matter supervision and/or mentoring, which is typically recorded in a competency workbook. Assessment is completed using appropriately qualified assessors who select the most appropriate method of assessment. Assessment may occur in an operational environment or in an industry-approved simulated work environment. Forms of assessment that are typically used include: direct observation interviewing the candidate journals and workplace documentation third party reports from supervisors written or oral questions. |
Range Statement
The Range Statement relates to the Unit of Competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording in the Performance Criteria is detailed below. | |
Explosive ordnance may include | Actuated devices Aerial delivered ordnance Demolition stores Free flight rockets Grenades Guided weapons Gun ammunition Missile and rocket motors Mortars Propellants Pyrotechnics and countermeasures Small arms ammunition Warheads |
Organisation may include | Defence organisation Enterprises that research explosive ordnance Other government departments or instrumentalities that research explosive ordnance |
Effects or properties to be determined may include | Explosive patterns Firing sequences Flight characteristics Human factors Initiation effects Pressures Terminal effects Trajectories Velocities |
Methods of measuring and recording may include | Flash x-ray photography High speed video/photography Infra red spectrophotometry Nuclear magnetic resonance spectrophotometry Spectrophotometry (UV, VIS) |
Occupational health and safety requirements may include | Calculation and maintenance of net explosive quantity Calculations of safety distances Maintaining compatibility Monitoring environmental conditions Safe handling of explosives and explosive ordnance |
Instrumentation may include | Electronic sensors Optical sensors Pneumatic and hydraulic sensors Specialised photographic equipment And may require the development of specialised computer programs to synchronise all instrumentation |
Sectors
Not applicable.
Employability Skills
This unit contains employability skills. |
Licensing Information