The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!
From the Wiki University
What evidence can you provide to prove your understanding of each of the following citeria?
Prepare to commission electronic unit
|
|
Organise resources based on identified existing and potential site hazards Completed |
Evidence:
|
Notify customer or network operations personnel to gain site access and network specifications Completed |
Evidence:
|
Determine type and complexity of electronic unit from specifications Completed |
Evidence:
|
Verify installed electronic unit and associated cabling conform to specifications Completed |
Evidence:
|
Establish commissioning dates and confirm with all parties Completed |
Evidence:
|
Determine commissioning parameters according to specification and establish planned outage as required Completed |
Evidence:
|
Obtain test equipment and check suitability and calibration status Completed |
Evidence:
|
Produce a preliminary commissioning plan for discussion with customer according to manufacturer instructions and enterprise guidelines Completed |
Evidence:
|
Inform affected customer/s of impending action and likely timing and impact of work Completed |
Evidence:
|
Organise planned outages
|
|
Negotiate outage times with appropriate groups and affected customer/s to minimise disruptions Completed |
Evidence:
|
Refer to contingency plans and arrange for emergency communications as required Completed |
Evidence:
|
Notify alarm management centre of planned action Completed |
Evidence:
|
Obtain authority to proceed from relevant control centre and notify customers affected by the outage Completed |
Evidence:
|
Perform commissioning procedures
|
|
Program equipment or install software according to manufacturer specifications and safety requirements Completed |
Evidence:
|
Set electronic unit parameters according to manufacturer specifications and customer requirements Completed |
Evidence:
|
Set-up test equipment and conduct tests according to manufacturer specifications and industry practice Completed |
Evidence:
|
Connect and test network access facilities for correct performance Completed |
Evidence:
|
Conduct cut over according to project design and industry practice in consultation with appropriate personnel Completed |
Evidence:
|
Check remote alarm and monitoring features are functional as required Completed |
Evidence:
|
Finalise commissioning documentation
|
|
Update relevant databases according to enterprise and network guidelines Completed |
Evidence:
|
Notify appropriate personnel of commissioning results and work completion Completed |
Evidence:
|
Complete administrative tasks according to telecommunications industry practice and enterprise guidelines Completed |
Evidence:
|