The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!

From the Wiki University

 

MEA504 - Maintain and fit oxygen masks

What evidence can you provide to prove your understanding of each of the following citeria?

Maintain oxygen mask

  1. Oxygen mask is inspected for serviceability in accordance with standard procedures
  2. Oxygen mask is tested for serviceability in accordance with standard procedures and manufacturer’s specifications
  3. Identified faults beyond own authority to rectify are reported to supervisor and faulty oxygen mask is quarantined
  4. Unserviceable parts of the oxygen mask are replaced in accordance with standards procedures while observing all relevant work health and safety (WHS) requirements, including the use of material safety data sheets (MSDS) and items of personal protective equipment (PPE)
  5. Communication system components are tested in accordance with standard procedures
  6. Oxygen mask is cleaned in accordance with standard procedures
  7. Oxygen mask is presented for inspection by supervisor in accordance with standard procedures
  8. Maintenance documentation is completed and processed in accordance with standard enterprise procedures
Oxygen mask is inspected for serviceability in accordance with standard procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Oxygen mask is tested for serviceability in accordance with standard procedures and manufacturer’s specifications

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Identified faults beyond own authority to rectify are reported to supervisor and faulty oxygen mask is quarantined

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Unserviceable parts of the oxygen mask are replaced in accordance with standards procedures while observing all relevant work health and safety (WHS) requirements, including the use of material safety data sheets (MSDS) and items of personal protective equipment (PPE)

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Communication system components are tested in accordance with standard procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Oxygen mask is cleaned in accordance with standard procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Oxygen mask is presented for inspection by supervisor in accordance with standard procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Maintenance documentation is completed and processed in accordance with standard enterprise procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Fit oxygen mask

  1. Fitting process is explained to the participant so that optimal fit can be achieved through relevant feedback
  2. Participant is measured to select an appropriate size oxygen mask
  3. Components of oxygen mask are adjusted to optimise fit
  4. Integration of the oxygen mask and helmet is confirmed for correct function during operations
  5. Oxygen mask fit is verified through participant feedback and by the supervisor
  6. Relevant documentation is completed and processed in accordance with standard enterprise procedures
Fitting process is explained to the participant so that optimal fit can be achieved through relevant feedback

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Participant is measured to select an appropriate size oxygen mask

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Components of oxygen mask are adjusted to optimise fit

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Integration of the oxygen mask and helmet is confirmed for correct function during operations

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Oxygen mask fit is verified through participant feedback and by the supervisor

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Relevant documentation is completed and processed in accordance with standard enterprise procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Assessed

Teacher: ___________________________________ Date: _________

Signature: ________________________________________________

Comments:

 

 

 

 

 

 

 

 

Instructions to Assessors

Evidence Guide

Elements describe the essential outcomes.

Performance criteria describe the performance needed to demonstrate achievement of the element.

1.

Maintain oxygen mask

1.1

Oxygen mask is inspected for serviceability in accordance with standard procedures

1.2

Oxygen mask is tested for serviceability in accordance with standard procedures and manufacturer’s specifications

1.3

Identified faults beyond own authority to rectify are reported to supervisor and faulty oxygen mask is quarantined

1.4

Unserviceable parts of the oxygen mask are replaced in accordance with standards procedures while observing all relevant work health and safety (WHS) requirements, including the use of material safety data sheets (MSDS) and items of personal protective equipment (PPE)

1.5

Communication system components are tested in accordance with standard procedures

1.6

Oxygen mask is cleaned in accordance with standard procedures

1.7

Oxygen mask is presented for inspection by supervisor in accordance with standard procedures

1.8

Maintenance documentation is completed and processed in accordance with standard enterprise procedures

2.

Fit oxygen mask

2.1

Fitting process is explained to the participant so that optimal fit can be achieved through relevant feedback

2.2

Participant is measured to select an appropriate size oxygen mask

2.3

Components of oxygen mask are adjusted to optimise fit

2.4

Integration of the oxygen mask and helmet is confirmed for correct function during operations

2.5

Oxygen mask fit is verified through participant feedback and by the supervisor

2.6

Relevant documentation is completed and processed in accordance with standard enterprise procedures

Required Skills and Knowledge

Elements describe the essential outcomes.

Performance criteria describe the performance needed to demonstrate achievement of the element.

1.

Maintain oxygen mask

1.1

Oxygen mask is inspected for serviceability in accordance with standard procedures

1.2

Oxygen mask is tested for serviceability in accordance with standard procedures and manufacturer’s specifications

1.3

Identified faults beyond own authority to rectify are reported to supervisor and faulty oxygen mask is quarantined

1.4

Unserviceable parts of the oxygen mask are replaced in accordance with standards procedures while observing all relevant work health and safety (WHS) requirements, including the use of material safety data sheets (MSDS) and items of personal protective equipment (PPE)

1.5

Communication system components are tested in accordance with standard procedures

1.6

Oxygen mask is cleaned in accordance with standard procedures

1.7

Oxygen mask is presented for inspection by supervisor in accordance with standard procedures

1.8

Maintenance documentation is completed and processed in accordance with standard enterprise procedures

2.

Fit oxygen mask

2.1

Fitting process is explained to the participant so that optimal fit can be achieved through relevant feedback

2.2

Participant is measured to select an appropriate size oxygen mask

2.3

Components of oxygen mask are adjusted to optimise fit

2.4

Integration of the oxygen mask and helmet is confirmed for correct function during operations

2.5

Oxygen mask fit is verified through participant feedback and by the supervisor

2.6

Relevant documentation is completed and processed in accordance with standard enterprise procedures

Evidence required to demonstrate competency in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria under the specified conditions of assessment, and must include:

applying WHS practices relating to oxygen mask maintenance processes

using MSDS

using applicable tools, testing/measuring equipment and maintenance documentation to:

solder oxygen mask electronic/electrical components

test the operation of helmet electronic/electrical components

replace unserviceable components in accordance with approved procedures

select and use appropriate oxygen mask cleaning materials

correctly fit oxygen masks to users

safely using the oxygen test rig

cleaning and maintenance of equipment and tools

correctly disposing of hazardous waste.

The underlying skills inherent in this unit should be transferable across a range of aircraft life support equipment maintenance activities. It is essential that oxygen mask testing and inspection procedures, cleanliness requirements and safety precautions are fully observed, understood and complied with. Ability to interpret maintenance and fitting procedures and apply them in practice is critical.

This is to be demonstrated through demonstration of the ability to recognise faults and damage and perform appropriate repairs that are within the bounds of the individual’s authority, and through the demonstration of correct fitting procedures.

Evidence required to demonstrate competency in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria and include knowledge of:

relevant enterprise procedures and maintenance publications

WHS procedures relating to oxygen mask maintenance

how to obtain MSDS

safety precautions relating to oxygen and the operation of the oxygen test rig

requirements for an oxygen mask servicing facility

oxygen in flight

components of an oxygen mask and their function

oxygen mask operation in relation to flight

oxygen regulator operation

physiological effects of flight

hypoxia

critical nature of maintaining and fitting oxygen masks

need to regularly assess correct fitment of oxygen masks

oxygen mask fitting procedures

fitting procedures relating to the fitment of oxygen masks to helmets

G forces

forces of ejection

basic electrical principles

environmental conditions that may affect oxygen equipment

approved cleaning methods for aviation life support equipment

handling, storage and transit procedures relating to life support equipment

handling and storage procedures for oxygen masks

types of corrosion and contamination that may affect oxygen masks

modification requirements for oxygen masks

oxygen mask repair procedures and limitations

soldering techniques

operation of testing and measuring equipment and tools used to maintain oxygen masks

use and storage of adhesives.

Range Statement

This field allows for different work environments and conditions that may affect performance. Essential operating conditions that may be present (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) are included.

Standard procedures are found in any or all of:

Commonwealth/state/territory WHS legislation, regulations and codes

Australian Standards

Equipment manufacturers’ specifications and procedures

Industry practices

Safety manuals

Maintenance schedules

Work instructions

Maintenance organisation manuals

MSDS

Defence regulations and instructions

Standing instructions

Faults include:

Contamination

Corrosion

Cracks

Excessive wearing

Fraying

Incorrect manufacture

Intermittent communication

Leaks

Perishing

Parts of the oxygen mask include:

Communication system (e.g. microphone)

Delivery tube

Exo-skeleton (e.g. outer shell)

Face piece (e.g. trimming)

Retention system (e.g. strap)

Valves

Communication system components include:

Microphone

Electric cables

Switches

Adjustable components include:

Retention system (e.g. strap)

Seals