The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!
From the Wiki University
What evidence can you provide to prove your understanding of each of the following citeria?
Use test instruments
|
|
Electron theory, current, voltage and resistance principles are understood. Completed |
Evidence:
|
Appropriate test instruments are selected, used and maintained to determine current, voltage and resistance. Completed |
Evidence:
|
Electrical drawings and manufacturers' diagrams are correctly interpreted. Completed |
Evidence:
|
Series, parallel and series parallel circuits are correctly determined. Completed |
Evidence:
|
Basic electrical laws are understood and correctly applied. Completed |
Evidence:
|
AVR test instruments are correctly connected into circuits. Completed |
Evidence:
|
Meters are read to standard accuracy; and wave form and quantities are determined using general purpose oscilloscope. Completed |
Evidence:
|
Multipliers and shunts are correctly used and applied. Completed |
Evidence:
|
Test battery
|
|
Chemical battery operating principles are understood. Completed |
Evidence:
|
Electrolyte level is correctly determined and specific gravity readings temperature is corrected. Completed |
Evidence:
|
Dry charge preparation and recharging of batteries is carried out correctly. Completed |
Evidence:
|
Discharge testing is performed according to prescribed procedures. Completed |
Evidence:
|
Replacement batteries are correctly selected for application. Completed |
Evidence:
|
Assess and rectify wiring faults
|
|
Wiring faults are correctly isolated. Completed |
Evidence:
|
Replacement cables/wires are correctly sized. Completed |
Evidence:
|
Insulation quality is correctly determined. Completed |
Evidence:
|
Wiring looms are correctly made up for application and securely fixed. Completed |
Evidence:
|
Wiring terminations are stripped, fitted, prepared and made correctly. Completed |
Evidence:
|
Corrosion is removed, neutralised and appropriate protective coating is applied. Completed |
Evidence:
|
Relays, solenoids, contacts and circuits are correctly tested and repaired/replaced. Completed |
Evidence:
|