The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!
From the Wiki University
What evidence can you provide to prove your understanding of each of the following citeria?
Prepare for glass laser measurement and levelling
|
|
Task requirements are determined by inspection of glass window and door components to be installed in a building and following relevant plans, drawings and texts in accordance with the work plan Completed |
Evidence:
|
Appropriate laser levelling equipment for the installation job is selected and set up to manufacturer recommendations Completed |
Evidence:
|
Levelling is planned in detail including sequencing and prioritising tasks and system requirements Completed |
Evidence:
|
Potential hazards to personnel and other building components at the installation site are identified and prevention and/or control measures are selected in accordance with the work plan Completed |
Evidence:
|
Individual’s roles and responsibilities within the installation team are identified, and where required, assisted with provision of on-the-job training for the tasks Completed |
Evidence:
|
Use laser devices to make measurements
|
|
Measurements are taken accurately, interpreted and recorded correctly to standard operating procedures Completed |
Evidence:
|
Laser levelling devices are operated to manufacturer specifications or standard operating procedures Completed |
Evidence:
|
Datum point is set up or located Completed |
Evidence:
|
Readings are taken to datum and at nominated or selected stations, to project specifications Completed |
Evidence:
|
Perform levelling
|
|
Levelling realignment calculations are performed using correct and appropriate method for the installation levelling/alignment application Completed |
Evidence:
|
Glass window and door components are levelled and aligned to specifications using correct and appropriate techniques, and adjustments made to ensure compliance with manufacturer specifications and the work plan Completed |
Evidence:
|
Glass components are temporarily fixed in the assigned installation positions prior to final measurement Completed |
Evidence:
|
Final level and alignment inspections are undertaken, any adjustments made and glass components fixed to the building using appropriate fasteners Completed |
Evidence:
|
Complete work
|
|
Glass installation rating compliance certificate is completed Completed |
Evidence:
|
Levelling equipment is closed own and appropriate personnel notified of completed installation in accordance with enterprise requirements Completed |
Evidence:
|
Work area is cleared of waste, cleaned, restored and secured in accordance with site/enterprise procedures Completed |
Evidence:
|
Plant, tools and equipment are maintained and stored in accordance with site/enterprise procedures Completed |
Evidence:
|
Work completion details are finalised in accordance with enterprise procedures Completed |
Evidence:
|