Joint and terminate coaxial cable

Formats and tools

Unit Description
Reconstruct the unit from the xml and display it as an HTML page.
Assessment Tool
an assessor resource that builds a framework for writing an assessment tool
Assessment Template
generate a spreadsheet for marking this unit in a classroom environment. Put student names in the top row and check them off as they demonstrate competenece for each of the unit's elements and performance criteria.
Assessment Matrix
a slightly different format than the assessment template. A spreadsheet with unit names, elements and performance criteria in separate columns. Put assessment names in column headings to track which performance criteria each one covers. Good for ensuring that you've covered every one of the performance criteria with your assessment instrument (all assessement tools together).
Wiki Markup
mark up the unit in a wiki markup codes, ready to copy and paste into a wiki page. The output will work in most wikis but is designed to work particularly well as a Wikiversity learning project.
Evidence Guide
create an evidence guide for workplace assessment and RPL applicants
Competency Mapping Template
Unit of Competency Mapping – Information for Teachers/Assessors – Information for Learners. A template for developing assessments for a unit, which will help you to create valid, fair and reliable assessments for the unit, ready to give to trainers and students
Observation Checklist
create an observation checklist for workplace assessment and RPL applicants. This is similar to the evidence guide above, but a little shorter and friendlier on your printer. You will also need to create a seperate Assessor Marking Guide for guidelines on gathering evidence and a list of key points for each activity observed using the unit's range statement, required skills and evidence required (see the unit's html page for details)

Self Assessment Survey
A form for students to assess thier current skill levels against each of the unit's performance criteria. Cut and paste into a web document or print and distribute in hard copy.
Moodle Outcomes
Create a csv file of the unit's performance criteria to import into a moodle course as outcomes, ready to associate with each of your assignments. Here's a quick 'how to' for importing these into moodle 2.x
Registered Training Organisations
Trying to find someone to train or assess you? This link lists all the RTOs that are currently registered to deliver ICTTC066D, 'Joint and terminate coaxial cable'.
Google Links
links to google searches, with filtering in place to maximise the usefulness of the returned results
Books
Reference books for 'Joint and terminate coaxial cable' on fishpond.com.au. This online store has a huge range of books, pretty reasonable prices, free delivery in Australia *and* they give a small commission to ntisthis.com for every purchase, so go nuts :)


Elements and Performance Criteria

Elements and Performance Criteria

Element

Performance Criteria

1

Prepare for jointing

1.1

Use safety equipment to protect self and public in accordance with enterprise guidelines and occupational health and safety practices

1.2

Read and interpret installation plan and physical conditions at site to determine layout of job

1.3

Copy of records is obtained, where appropriate

1.4

Locate and identify adjoining services in accordance with enterprise guidelines and occupational health and safety practices

1.5

Test for presence of dangerous gases in accordance with enterprise guidelines

1.6

Approved alterations to the design are undertaken in accordance with enterprise guidelines

2

Verify coaxial cable placement

2.1

Cable segregation is maintained to industry standard requirements

2.2

Protect integrity of the coaxial shield cable to ensure no loss of continuity

2.3

Minimum bend radius in not exceeded in accordance with manufacturer's specifications

2.4

Cable is placed in position with sufficient slack to allow termination

2.5

Cable placement follows installation designs and specifications accurately

2.6

Cable is installed in a safe manner without damage to cable or customer's premises

2.7

Cable lengths do not exceed manufacturer's or design specifications to maintain radio frequency signal strength

3

Secure coaxial cable

3.1

Locate securing hardware to reduce the cumulative effect on cable wave shape properties

3.2

Cable ties and brackets are flexible and do not damage cable during securing or while in use

4

Joint coaxial cable

4.1

Strip coaxial cable in accordance with specifications to required length using appropriate tool

4.2

Select appropriate kit to match the type of coaxial cable in use

4.3

Jointing method is in accordance with manufacturer's recommendations

4.4

Jointing fitting retains the segregation of conductor and shield

4.5

All joints are sealed in accordance with manufacturer's specifications

5

Terminate coaxial cable

5.1

Strip coaxial cable in accordance with specifications to required length using appropriate tool

5.2

Select connectors to match the type of coaxial cable in use

5.3

Terminating method is in accordance with manufacturer's recommendations

5.4

Connector fitting retains the segregation of conductor and shield

5.5

Connectors are terminated to torque as recommended by manufacturer's to ensure no radio frequency leakage can occur

5.6

Gauge tests are carried out to connector mating specifications

5.7

The termination maintains a continuous ground

5.8

All terminations are waterproof where appropriate to minimise risk of damage to termination and cable function

6

Complete splicing operation

6.1

Place cables in enclosure and lay up in accordance with manufacturer's instructions and enterprise guidelines

6.2

Other cables are tidy and no safety hazards are evident

6.3

Other services are in place in accordance with enterprise guidelines

6.4

Waste and debris are removed from worksite and disposed of in accordance with environmental requirements and to maintain safe worksite conditions

6.5

Site is reinstated and tools and materials are stored in accordance with enterprise guidelines

7

Complete installation administration

7.1

Complete reports in accordance with enterprise policy

7.2

Note alterations to plans using appropriate symbols